The extent of errors associated with contact angles II. Factors affecting data obtained using a Wilhelmy plate technique for powders

Sheridan, P.L., Buckton, G. and Storey, D.E. (1994) The extent of errors associated with contact angles II. Factors affecting data obtained using a Wilhelmy plate technique for powders. International Journal of Pharmaceutics, 109 (2). pp. 155-171. 10.1016/0378-5173(94)90143-0.

Full text not available from this repository.

DOI: 10.1016/0378-5173(94)90143-0

Abstract

The reasons for error, and the magnitude of error that may be expected have been investigated for Wilhelmy plate contact angle measurements on compacted plates. A range of different materials have been considered, including a homologous series of powders (alkyl p-hydroxybenzoates), and α-lactose monohydrate (from three different suppliers). The effect of powder and plate storage conditions, the compaction force and dwell time used to prepare the plate, and the approach to defining the buoyancy slope of the Wilhelmy plate experiment have all been considered. The effect of compaction seems to be material dependent, some materials are unaffected by large changes in applied pressure, whilst others are particular sensitive to changes in the compaction process. Propyl p-hydroxybenzoate was especially sensitive to changes in compaction, such that even when trying to produce identical compacts, variability was noted for different days of plate preparation. Variability in measured contact angle was not associated with humidity equilibration, or time after the plate was made for the materials studied. The major cause of variability in the contact angle seemed to be the plate roughness. There is some concern that the plate roughness will not only affect the result by normal hysteresis effects, but also because the measured perimeter (external dimensions) will underestimate the true perimeter of a rough plate. Having noted many causes for concern with this technique, it was observed that standard deviations for the contact angles were smaller than for other contact angle techniques for powdered samples, however, accuracy and precision should not be confused.

Item Type:Article
Departments, units and centres:Department of Pharmaceutics > Department of Pharmaceutics
ID Code:3279
Journal or Publication Title:International Journal of Pharmaceutics
Deposited By:Library Staff
Deposited On:18 May 2012 15:54
Last Modified:18 May 2012 15:54

Repository Staff Only: Item control page

School of Pharmacy Staff Only: Edit a copy to replace this item